4.0 mL Green top (lithium heparin) vacutainer or heparinized syringe 600 uL
Collection Volume:
4.0 mL or 600 uL (minimum 400 uL)
Cause for Rejection:
Clotted, air bubbles. Specimens collected in microtainer tubes will be rejected.
Storage:
Room Temp
Availability:
Daily, 24 hours: STAT
Methodology:
Ion selective Electrode/ Calculations
Special Instructions:
Notify laboratory if patient's temperature is other than 37 C to correct results (temperature dependent). Deliver immediately to laboratory at room temperature.
This test can only be drawn at a location with an on-site laboratory.
Lab/Phone:
330-746-9623
TAT:
30 minutes
Additional Info:
Reference ranges available under individual tests.