Laboratory :
Chemistry
Test ID/Workstation :
CA MACH1
Tube Type:
Green top (lithium heparin)tube
Cause for Rejection:
Do not use anticoagulants such as citrate, oxalate or EDTA.
Availability:
Daily, 24 hours; STAT
Methodology:
Calcium ion reaction with 5-nitro-5-methyl-BAPTA
Special Instructions:
The only acceptable anticoagulant is Li heparin. Plasma should be separated from blood cells as soon as possible.
Additional Info:
Reference range: 7.6-22.0 mg/d/L